Liquid Particulate Removal Unit
The Busch Purifier is a high
velocity, inline cyclonic eliminator
designed to collect liquid particulate
from an airstream This device is
the standard mist removal method
for rolling mills in the metals
industry, cleaning over 2.5 million
scfm since first introduced in
1968.
The highly effective PURIFIER,
which employs a two stage design
is self-cleaning and has no moving
parts. As the contaminated gas
enters the unit and strikes an
impingement head, larger particles
are removed. The gas then passes
through a vaned element which redirects
the entrained liquid to the inside
surface of the shell where it is
collected and drained away. Specific
application options such as sprays
for element cleaning, shell and
drain heat tracing and insulation
may be added as required to improve
operation and maintenance characteristics.
The PURIFIER handles coolant
laden air at a constant pressure
drop and is highly efficient in
removing most liquid particulate
10 microns and larger in size.
The design
of the PURIFIER is unique in comparison
to other centrifugal mist eliminatorssince
it has been specifically designed
for rolling mill coolant removal
applications. Several of the more
recent modifications include relocation
of drains to handle dirt contaminated
coolants, redesign of drain troughs
to a sloped configuration to enhance
drainage of higher viscosity liquids,
relocation of access doors to reduce
re-entrainment and a reduction
in thenumber of element supports
to improve airflow characteristics.
Principal
components of the PURIFIER include
a vaned separating element of
type 304stainless steel and a
vessel shell of minimum 1/4î steel
plate. Hinged access doors are
provided in each compartment. These
doors are equipped with cam-level
fasteners and safety bolts to prevent
accidental opening. Unit support
legs are available. |